Log Out Log Out Log Outopen invoices
Language:
EnglishEspañol
My Shopping Cart
Your shopping cart is empty
Need help? Reach us at 1800.325.9708 Live Support
Access Power Controller Board, 4 Fused Relay Outputs, FAI Altronix ACM4
View Larger

Access Power Controller Board, 4 Fused Relay Outputs, FAI

Item # ACM4
Manufacturer Item # ACM4
          
Log In To View
Prices

Sold As: EA
Altronix
More Products from Altronix
  Add to Shopping List
  Save For Later
  Share

Overview

Access Power Controller Board, 4 Fused Relay Outputs, FAI
Altronix ACM4 converts one (1) 12 to 24 VAC or VDC input into four (4) independently controlled fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM4 will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes.
Units are designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs.

Features:
  • Input

       12 to 24 volt AC or DC operation (setting not required), (0.4A @ 12volt, 0.2A @ 
       24 volt current consumption with all relays energized).

         Power supply input options:
          a) One (1) common power input (board and lock power).
          b) Two (2) isolated power inputs (one (1) for board power and one (1) for lock/accessory power).
        
         Four (4) Access Control System trigger inputs:
          a) Four (4) normally open (NO) inputs.
          b) Four (4) open collector sink inputs.
          c) Any combination of the above.
     
  • Output

        Four (4) independently controlled outputs:
          a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
          b) Four (4) dry form "C" 5A rated relay outputs
          c) Any combination of the above
        Four (4) auxiliary power outputs (unswitched).
           Output ratings:
             Fuses are rated 2.5A each.
             Main fuse is rated at 10A.
             Note: Total output current is determined by the power supply, not to exceed a maximum of 10A. total.
     
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the four (4) outputs.
         Fire Alarm disconnect input options:
          a) Normally open (NO) or normally closed (NC) dry contact input.
          b) Polarity reversal input from FACP signaling circuit.
  • FACP output relay (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Removable terminal blocks facilitate ease of installation.

Specifications

  Product NameAccess Power Controller Board, 4 Fused Relay Outputs, FAI
  Brand NameAltronix
  Mfg #ACM4
  Cube240 cu in
  Length5.18 in
  Width3.36 in
  Height1.25 in
  Weight0.35 lbs
  Operating Voltage12 / 24 VAC/VDC

Documents

ACM4.pdf