END THE RADIO SILENCE
Fiplex FLEX Series BDA | Mission-Critical Public Safety In-Building Coverage
The Evolution of Emergency Communications
Modern building materials — concrete, low-E glass, steel structures — create dead zones that block critical radio signals. For first responders, every second counts. Fiplex FLEX Series BDA (Bi-Directional Amplifier) eliminates communication failures, ensuring that police, fire, and EMS have seamless, reliable radio coverage throughout your facility. Unlike traditional signal boosters, the FLEX Series is a software-defined, future-ready platform that adapts to any jurisdiction’s requirements.
From Class B band selective to Class A channel selective operation, and from 0.5W to 5W output power, FLEX Series BDAs are the industry’s most flexible, user friendly mission critical solution. With UL2524 2nd Edition listing, built-in oscillation detection, automatic uplink shutdown, and full alarm integration, Fiplex delivers the confidence that AHJs, A&Es, and building owners demand.
Trusted by First Responders Nationwide
The FLEX Series meets IBC 2021 Section 916, NFPA 1 2021, IFC 2021, NFPA 1225 2022, and is FCC certified under 47 CFR Part 90.219. It’s the only BDA solution that combines software-defined programmability, per channel AGC, and a dedicated annunciator-ready architecture.
FLEX Series – Engineered for Code Compliance & Performance
CLASS A / B FLEXIBILITY
Software upgradeable from band selective (Class B) to channel selective (Class A) with 32 independent channel filters per band. Adjustable bandwidths from 12.5kHz to 150kHz.
UL2524 2nd EDITION
SGS NRTL approved (OSHA recognized). Meets the latest UL standard for in building two way emergency radio communication enhancement systems.
NOISE & OSCILLATION PREVENTION
Automatic uplink power amplifier shutdown, programmable mitigation actions, and real time oscillation detection ensure zero interference with public safety networks.
Software-Defined Intelligence for Mission-Critical Reliability
The FLEX Series BDA isn’t just an amplifier — it’s a fully digital, FPGA based platform that provides per channel and per timeslot Automatic Gain Control (AGC). This granular control eliminates near far effects and ensures consistent signal strength even in dense urban environments or multi tenant buildings.
- Channel Selective (Class A) Mode: Amplifies only the specific public safety channels (bandwidth <75kHz), reducing noise and improving spectral efficiency. Ideal for jurisdictions requiring precise frequency control.
- Band Selective (Class B) Mode: Covers entire public safety bands (700/800 MHz, VHF, UHF) simultaneously — perfect for broad coverage where all channels must be boosted.
- Automatic Gain Control per Timeslot: On P25 Phase II or DMR systems, AGC adjusts dynamically per time slot, preventing desensitization of donor base stations.
- Remote Alarm & Annunciator Integration: Dry contact outputs and optional dedicated annunciator panel (built in BBU or remote) provide full visibility to fire alarm control panels (FACP).
FLEX Series BDA – Compact, NEMA 4 rated, with integrated battery backup option
Solving the Coverage Problem – Code by Code
ERCES Mandate
IBC 2009 first introduced Emergency Responder Communication Enhancement Systems (ERCES). Today, IBC 2021, NFPA 1, and IFC 2021 require approved in building coverage based on existing public safety signals at the exterior.
RF Survey & Heat Mapping
FCC GROL certified technicians measure downlink/uplink signal strengths (dBm). Results submitted to AHJ determine if a BDA/DAS is required. Fiplex supports predictive modeling and on site verification.
Annunciator & FACP Monitoring
NFPA requires a dedicated annunciator panel at fire command center. FLEX Series provides built in annunciator in the BBU plus remote annunciator options, with dry contacts for full fire alarm integration.
FLEX Series BDA: The Industry’s Most Adaptable Public Safety Signal Booster
Fiplex’s FLEX Series BDA (Bi-Directional Amplifier) is engineered specifically for in building public safety radio coverage. Whether you’re retrofitting a high rise, a hospital, a tunnel, or a campus, the FLEX Series delivers reliable, code compliant amplification for VHF, UHF, 700 MHz, 800 MHz, and FirstNet Band 14 — all within a single, software configurable platform. Its unique ability to upgrade from Class B to Class A via license, and from 0.5W to 5W output power, ensures that your investment grows with regulatory changes and building expansions.
Key Features of FLEX Series BDA
Software-Programmable Bandwidth
Adjustable from 100kHz to full band in steps of 50kHz (BWA mode), or select channel filters from 12.5kHz to 150kHz after Class A upgrade. This flexibility meets any AHJ’s frequency allocation plan.
Per-Channel & Per-Timeslot AGC
Downlink Automatic Gain Control operates independently per channel or per time slot (P25 Phase II, DMR). Prevents uplink noise from overwhelming the donor site while maintaining uniform coverage.
Oscillation Detection & Auto-Shutdown
Real time monitoring of antenna isolation. If oscillation risk is detected, the BDA automatically shuts down or reduces gain to prevent interference with public safety networks. Programmable mitigation actions give integrators fine control.
UL2524 2nd Edition Listing
Tested and certified by SGS (NRTL). The FLEX Series meets the stringent requirements for in building two way emergency radio communication enhancement systems, ensuring AHJ acceptance and faster permitting.
Core Benefits for Building Owners & Integrators
1. Future Proof Investment – Upgrade Without Hardware Replacement
Start with a Class B band selective BDA at 0.5W to meet basic code requirements. Later, if the AHJ mandates channel selective operation (Class A) or higher power (up to 5W), simply purchase a software license — no need to rip and replace hardware. This dramatically reduces total cost of ownership and downtime.
2. Zero Noise, Zero Interference – Protect Public Safety Networks
The FLEX Series incorporates advanced uplink noise suppression and squelch functions. The assisted GUI wizard and automatic calibration (patent-pending) reduce uplink noise contribution, preventing desensitization of macro base stations. Oscillation prevention and automatic power amplifier shutoff ensure the BDA never becomes a source of interference — a critical requirement under FCC 47 CFR Part 90.219.
3. Seamless Fire Alarm Integration – Annunciator & Dry Contacts
NFPA 72 and NFPA 1225 require that BDA status (normal, alarm, battery trouble) be displayed at the fire command center. FLEX Series includes a built in annunciator in the Battery Backup Unit (BBU) and supports remote annunciator panels. Multiple dry contact relays provide connection to the building’s fire alarm control panel (FACP), satisfying AHJ requirements without extra hardware.
4. Simplified Installation & Commissioning
With its NEMA 4 weatherproof enclosure, integrated 24 hour battery backup (optional), and USB local management, the FLEX Series reduces installation complexity. The assisted GUI wizard walks technicians through automatic calibration, gain setting, and squelch configuration, ensuring optimal performance in minutes.
Class A vs Class B – What’s Right for Your Building?
Class A (Channel Selective)
- Bandwidth per channel <75 kHz (typically 12.5/25 kHz).
- Amplifies only specific licensed public safety channels.
- Mitigates near far effects; ideal for dense urban areas or where multiple BDAs share the same donor site.
- Must be registered with FCC (per 47 CFR 90.219).
- FLEX Series supports up to 32 independent channel filters.
Class B (Band Selective)
- Bandwidth >75 kHz (covers entire public safety band).
- Simpler, more common for smaller buildings.
- Boosts all channels within 700/800 MHz simultaneously.
- Requires direct FCC registration before use.
- FLEX Series offers adjustable BWA filters from 100kHz to full band.
Technical Specifications – FLEX Series BDA (Single/Dual Band)
RF & Operational Parameters
| Frequency Bands | VHF, UHF, 700 MHz, 800 MHz, FirstNet Band 14 (single or dual band models) |
|---|---|
| Max Gain | 85 dB (adjustable, 30dB range in 1dB steps) |
| Output Power (per band) | 0.5W / 2W / 5W (model dependent, software upgradeable) |
| Noise Figure | ≤ 9 dB (typical) |
| Group Delay (Channel Selective) | 12.5kHz: 63µs ; 25kHz: 35.8µs ; 150kHz: 11.6µs |
| Connectors | N(f) standard, 50 Ohms |
Environmental & Compliance
| Housing | NEMA 4 / IP66 (weatherproof, indoor/outdoor) |
|---|---|
| Temperature Range | -13°F to 131°F (-25°C to +55°C) |
| Power / Battery Backup | AC 110V with optional 24hr battery backup (lead acid) |
| Standards | UL2524 2nd Ed., IFC 2021, IBC 2021, NFPA 72, NFPA 1225, FCC Part 90 |
| Management | USB local access, dry contact alarms, LED annunciator, remote annunciator option |
Frequently Asked Questions (Based on NFPA & AHJ Guidelines)
What are NFPA’s requirements for annunciator at FACP?
A dedicated annunciator panel must be located in the fire command center or other location designated by the AHJ. The BDA and Fiber DAS Master/Remote status must also be monitored by the building’s fire alarm system. FLEX Series provides dry contact outputs and optional remote annunciator for full compliance.
Does the building code require BDAs for Police and Fire?
Yes. The code requires coverage for all emergency responders as determined by the AHJ — typically Fire, Police, EMS, and mutual aid. FLEX Series supports all public safety frequency bands, including mutual aid channels.
How do I determine if my building needs a BDA?
An RF Survey performed by an FCC GROL certified technician measures downlink/uplink signal strengths (dBm) throughout the building. Results are submitted to the AHJ. If coverage fails to meet minimum requirements (e.g., 99% coverage of critical areas), an ERCES (BDA/DAS) is required. Fiplex offers pre-construction predictive modeling and post-construction verification.
What technician qualifications are required?
Typically FCC GROL (General Radiotelephone Operator License) or approved equivalent, plus manufacturer-specific certification. Fiplex provides training and certification for integrators.
Summary – Why First Responders Trust FLEX Series
The Fiplex FLEX Series BDA is not just another signal booster — it’s a complete, code compliant, future ready ecosystem for in building public safety communications. From software-defined channel selectivity to automatic oscillation prevention and UL2524 2nd Edition listing, it delivers the reliability that fire marshals, building owners, and system integrators demand. Whether you need a standalone Class B amplifier or a high power Class A channel selective system, FLEX adapts to your jurisdiction’s unique requirements. End the radio silence. Protect the people who protect you.
Resources & Official References
- Fiplex FLEX Series Official Product Page: https://www.fiplex.com/flex-in-building-solution-2023/#bda
- UL2524 2nd Edition Certification – SGS NRTL
- NFPA 1225 (2022) Chapter 18 – Emergency Responder Radio Coverage
- IBC 2021 Section 916 – Emergency Responder Communication Enhancement Systems
- FCC 47 CFR Part 90.219 – Signal Boosters
Ensure Code Compliance & First Responder Safety
Contact us to request a FLEX Series BDA quote for your building.
Contact us